Electronic and Automatic Primary Injection Test System (eKAM)

Sepete ekleyerek toplu teklif isteyebilirsiniz

Diğer

Electronic and Automatic Primary Injection Test System (eKAM)

eKAM test system includes two portable units: one control unit with a large graphical display that adjusts the AC voltage output (up to 220 V) and one current unit (up to 2000, 3000, 5000A). BUX 2000 (2000 A) - BUX 3000 (3000 A) - BUX 5000 (5000 A): one or more BUX current unit can be connected to eKAM (not simultaneously), they can be ordered separately when the order is placed or at a later moment. With the control knob and the LCD display, it is possible to enter the MENU mode, that allows to set many functions, making eKAM a very powerful testing device, with manual and automatic testing c...

Açıklama

eKAM test system includes two portable units: one control unit with a large graphical display that adjusts the AC voltage output (up to 220 V) and one current unit (up to 2000, 3000, 5000A). BUX 2000 (2000 A) - BUX 3000 (3000 A) - BUX 5000 (5000 A): one or more BUX current unit can be connected to eKAM (not simultaneously), they can be ordered separately when the order is placed or at a later moment. With the control knob and the LCD display, it is possible to enter the MENU mode, that allows to set many functions, making eKAM a very powerful testing device, with manual and automatic testing capabilities and with the possibility to transfer test results to a PC via ETHERNET or Pen Drive. The TDMS software, which comes with the test set, allows to download, display and analyze test results obtained in local mode. Remote maintenance and diagnostic of the instrument are available via Ethernet. TDMS software operates with all Windows ® versions. The ease of operation has been the first goal of eKAM. This is why the LCD display is so large and the dialogue in the MENU mode is made easy. eKAM includes three measurement inputs:
  • . DC voltage (10 V DC).
  • . AC voltage:
  • .. High range (300 V AC)
  • .. Medium range (10 V AC)
  • .. Low range (3 V AC)
  • . Current (10 A AC or DC).
All these inputs are independent among them (unless 3V and 300V) and allow the measurement of CT outputs or of another source. In addition, a digital input (up to 300 V) is available: it can measure the timing of a wet or dry contact. The instrument is housed in a transportable aluminium box, which is provided with a cover and handles for ease of transportation. A transport case can also be supplied upon request.