Microtest 7120 Single-Phase Power Meter

Sepete ekleyerek toplu teklif isteyebilirsiniz

MICROTEST

Microtest 7120 Single-Phase Power Meter

Features AC / DC Dual amp/watt-hour meter Wide range 0.001W-16KW Connection software attached Standby Power D.P.I. of 0.001W With crest factor ratio display Up to the 50 levels harmonic wave analysis capability 1000 sets of measurement data storage space Current crest factor is highest CF9

Açıklama

  

Specifications

Selection

Model 7110 7120
Frequency Range DC, 15Hz~10KHz DC, 15Hz~100KHz
Harmonic (option) ● / - ● / -

Measurement Parameters

Parameters Range Parameters Range
Vrms 0.1V ~ 600V PF 0.000 ~ ±1.000
Vdc 0.1V ~ 600V Deg -180°~ +180°
Irms 0.1mA ~ 20A THD 0.01% ~ 99.99%
Idc 0.1mA ~ 20A Hz 15Hz ~100kHz
W 0.01W ~16KW

Measurement Range

Current (fixed/Auto) 0.01A 、0.03A、0.1A、0.3A、1A、3A、10A、20A
Voltage (fixed/Auto) 10V 、30V、100V、300V、600V

Harmonics SPEC

Analysis base To achieved stable fundamental frequency analysis by voltage or current (non-inverter)
Frequency Range 45Hz 45Hz - 440Hz
FFT Data Length 1024
FFT Data Format 32 bits
Measurement Projects
  • 1-50 THD, 1-50 level voltage and current V [n], A [n]
  • 1-50 level voltage and current distortion percentage
  • V [n%], A [n%]
  • 1-50 level watts W [n]
  • 1-50 level watts distortion percentage Watt W [n%]
  • 1-50 level voltage and current angle DEG [n]
  • Vrms, Irms, Watt, PF

SPEC

Model 7110 7120
Frequency Measurement Mode To achieved stable base frequency measurement (variation less than 1%) by voltage or current (non-inverter)
Frequency Range DC, 15Hz~10KHz DC, 15Hz~100KHz
Data Length Dual 4096x16 RAM for voltage & current
ADC Resolution 16 bits
Sampling Rate AC 50Hz/60Hz basic sampling rate 100 KSPS /120 KSPS
Arithmetic Precision Watt/VRMS/IRMS/MEAN/PF/Deg/Line filter 32bits
Frequency Filter 500Hz cut off, digital chip filter based on 25MHz
Signal Filter 500Hz-3db digital filter based on Butterworth 50Hz-0.03% reading, 60Hz-0.05% reading
Frequency Acquisition Mode Voltage / current 100MHz baseband digital dynamic meter chip
Phase Lead Detection Subject to the current, analog/digital hybrid detecting (error less than 5 degrees)
RMS/MEAN Mode Voltage & Current Accuracy (23℃ ±5℃ )
>=15 Hz, f ≦ 45Hz   ±(0.1% of reading + 0.4% of range)
>45 Hz, ≦ 66 Hz   ±(0.1% of reading + 0.1 % of range)
>66 Hz, ≦ 1 kHz   ±(0.1% of reading + 0.2 % of range)
>1 kHz, ≦ 10 kHz   ±(0.07*f % of reading + 0.3% of range)
>10 kHz, ≦100 kHz   ±(0.5% of reading + 0.5% of range) ±[{0.04×(f–10)}% of reading]
Funit is 1KHz When the L-FILTER sets as ON: 45Hz~66Hz frequency range allowable error-0.03 %~-0.05 of reading
When the AC is measured, if the fundamental frequency exceeds 200Hz, the F-Filter is required to be turned off in order to measure the most accurate value**When the frequency range is more than 10KHz, the 7120 starts to support
DC Mode Voltage & Current Accuracy (23℃ ±5℃ )
10V~600V   ±0.2% reading ± 0.2% of range
0.01A ~20A   ±{(0.2)% of reading + 0.2 % of range} ±offset
To add up the OFFSET errors of various files during measuring the DC current
Power (W) Accuracy (23℃ ±5℃ )
 AC power ranges (Auto or Manual)(40 ranges) range up to 16KW Maximum Power (W) value is determined by the highest range of voltage profile
  DC ±0.2% reading ± 0.5% of range
  • 15 Hz≦f
  • 66 Hz
  • 1 kHz
  • 10 kHz
Incidental Allowable Error Conditions
  Signal Filter Error (AC)
  • Frequency between 45-66Hz: Add 0.3% of reading.
  • Frequency between45-66Hz: Add 1% of reading beyond
  CF9 Error (DC)      Add range tolerance * 3
Accuracy Effect of the Phase Error of the Power
When the power factor PF is 0, the error range of Watt is Situation 1: for 45Hz < f, Add±1.0% of VA Situation 2: for 45Hz > f or f > 66Hz Add ±{(3.5 + 0.5×f )% of VA} for up to 100kHz as reference data The unit for frequency f is kHz. When the power factor is 0 < PF≦error range When 0 < PF ­ 1 (θ: phase angle of the voltage and current) for 45Hz ­ f ­ 66Hz. Add ±power reading *{tan(θ)*(0.5)}% for f < 45Hz, f > 66Hz. Add ±power reading *{ tanθ*(0.5×f+0.2) }%
 Error within 12 months   Add ±(0.5% of reading)

SYSTEM

Model Support Harmonics 7110-10k-HARM Support Harmonics 7120-100k-HARM
Don't Support Harmonics 7110-10k Don't Support Harmonics 7120-100k
F71201 TEST BOX
Built-in stroage 6 Sets
Power Supply Voltage 100 ~ 240Vac
Frequency 50/60Hz
Power consumption 300VA
Environment Temperature 23℃±5℃
Humidity 20%-80%RH
Display Seven-segment display
Dimension (W*H*D) 227x101x300 mm
Weight 1.85 Kg
Interface RS-232 (7110)、RS232 + GPIB (7120)